Global Gauge Corporation
PERFECTA X-SERIES · 100 KV · SIEMENS

Perfecta-100-S
Thickness Gauge

100 kV X-ray thickness gauge for cold mill strip, engineered on Siemens S7-1500 with PROFINET. Purpose-built for tandem mill AGC loops at European and Asian mills.

THICKNESS RANGE
0.020 – 0.500 in.
ACCURACY
± 0.1%
RESPONSE TIME
< 2 ms
X-RAY SOURCE
100 kV
Doc P100SI-26 · Rev BReplaces P100SI-22ISO/IEC 17025 calibrated
Perfecta C-frame thickness gauge
Front
Detector
Tube Head
Cabinet
HOW IT WORKS

Cold-mill thickness, on Siemens

01

100 kV X-ray transmission

Air-cooled 100 kV tube optimized for cold-rolled strip densities from aluminum to stainless.

02

Alloy-corrected signal

Temperature and alloy compensation applied in under 2 ms, across 18 standard alloys.

03

PROFINET publish

Thickness published over PROFINET to Siemens S7-1500 at up to 1 kHz for AGC feedback.

04

Remote diagnostics

EXOR MicroEdge remote access with tiered support plans from Dayton and our regional partners.

FULL SPECIFICATIONS

Perfecta-100-S technical data

Measurement
Measurement principleX-ray transmission, constant potential
Thickness range0.020 to 0.500 in. (0.51 to 12.7 mm)
Accuracy± 0.1% of nominal
Response time< 2 ms to 63% step
Repeatability (2σ)± 0.05% of nominal
Alloy compensation18 alloys standard
X-ray Source
Source typeConstant-potential, air-cooled
Tube voltage100 kV maximum
Tube current0.5 to 8 mA
Warm-up time< 3 minutes from cold start
Controls & Electrical
PLC platformSiemens S7-1500 (CPU 1515 / 1518)
ProtocolPROFINET, OPC UA
HMIEXOR MicroEdge 15.6 in. color touch
Power230/400 VAC, 50/60 Hz, 3 kVA
Mechanical
Frame typeC-frame, motorized retract
Throat depth20 in. (508 mm) standard
Strip speedUp to 4,000 ft/min (1,219 m/min)
Ambient temperature0 to 50 °C operating
SPEC THE PERFECTA-100-S

Get a budgetary quote.

Tell us your strip dimensions, line speed, and existing PLC architecture. Our applications team will return a complete proposal with installation schedule.