100 kV X-ray thickness gauge for cold mill strip, engineered on Siemens S7-1500 with PROFINET. Purpose-built for tandem mill AGC loops at European and Asian mills.
Air-cooled 100 kV tube optimized for cold-rolled strip densities from aluminum to stainless.
Temperature and alloy compensation applied in under 2 ms, across 18 standard alloys.
Thickness published over PROFINET to Siemens S7-1500 at up to 1 kHz for AGC feedback.
EXOR MicroEdge remote access with tiered support plans from Dayton and our regional partners.
| Measurement principle | X-ray transmission, constant potential |
| Thickness range | 0.020 to 0.500 in. (0.51 to 12.7 mm) |
| Accuracy | ± 0.1% of nominal |
| Response time | < 2 ms to 63% step |
| Repeatability (2σ) | ± 0.05% of nominal |
| Alloy compensation | 18 alloys standard |
| Source type | Constant-potential, air-cooled |
| Tube voltage | 100 kV maximum |
| Tube current | 0.5 to 8 mA |
| Warm-up time | < 3 minutes from cold start |
| PLC platform | Siemens S7-1500 (CPU 1515 / 1518) |
| Protocol | PROFINET, OPC UA |
| HMI | EXOR MicroEdge 15.6 in. color touch |
| Power | 230/400 VAC, 50/60 Hz, 3 kVA |
| Frame type | C-frame, motorized retract |
| Throat depth | 20 in. (508 mm) standard |
| Strip speed | Up to 4,000 ft/min (1,219 m/min) |
| Ambient temperature | 0 to 50 °C operating |
200 kV X-ray gauge for heavy strip on Allen-Bradley.
Dual-side coating weight gauge for galvanizing lines.
Stereo line-scan width gauge for slitting lines.
Tell us your strip dimensions, line speed, and existing PLC architecture. Our applications team will return a complete proposal with installation schedule.