Accura Thickness Gauge

Accura Thickness Gauge

The Industry Standard In PC-Based Gauging

Accura Thickness

Accura Thickness Gauge

Fast | accurate | dependable | Cost-Effective

The Accura Gauge was born from an industry request to create a cost-effective, high-speed, non-contact gauge system, based on off-the-shelf industrial PC technology. From the first installation the Accura has exceeded customer’s expectations. The system maximizes the use of top quality, off-the-shelf components, including a robust industrial PC. The gauge software was specifically developed by GGC engineers to take advantage of high speed processors available in today’s industrial PCs. The resultant gauge system is extremely fast, well beyond the requirements of most closed-loop mill control systems. Accura gauges are installed all over the world on rolling mills and process lines. This gauge is suitable for measuring the thickness of metals (ferrous and non-ferrous), plastics, ceramics, and many other types of materials.

Why Choose the Accura Thickness Gauge?

Industrial PC-Based Design

Relied upon leading manufacturers for consistent precision.

Configurable I/O

Engineered to withstand extreme mill environment with high durability.

rittal cabinet

Integrates with leading PLC/SCADA systems like Siemens & Allen-Bradley.

High Speed
Precision

Industry-proven performance for high-speed precision

Accura Thickness Gauge Specifications

MEAN RESPONSE TIME

“The mean time after a step variation in the measured quantity until the output signal reaches a specified percentage of its final mean value for the first time. For this standard, 63.2% of the step change shall be the specified percentage.”
(IEC 1336, 1.3.24.1)

Response Time
<2mS per Test Point A (IEC 1336, 1.3.7.1)

STATISTICAL NOISE

“Variation of the output signal under reference conditions, while all influence quantities are held constant and the detector is in an irradiated condition.”
(IEC 1336, 1.3.22)

Statistical Noise
@10mS the 2σ variation = ± 0.12%

ACCURACY

“Degree of conformity of an indicated value to a recognized standard value, or ideal value.”
(IEC 1336, 1.3.14)

In the case of Thickness Gauges, the standard value is usually a precision master (internal or external) on which the gauge has been standardized. Accuracy is usually expressed as a percentage of the nominal thickness being measured.

Accuracy
The nominal 2σ = ± 0.1%, not better than ± 0.2μm

DRIFT

Drift is expressed as a percentage of the nominal thickness being measured.

Short Term ~1 hour
≤ ± 0.050% from the set thickness,
not better than ± 1μm

Long Term ~8 hours
≤ ± 0.1% from the set thickness,
not better than ± 2μm

REPRODUCIBILITY

“Closeness of agreement among a number of consecutive measurements of the gauge output signal for the same input and under the same operating conditions.”
(IEC 1336, 1.3.15)

Reproducibility
≤ ± 0.1% from the set thickness,
not better than ± 5μm

Repeatability
≤ ± 0.050% from the set thickness,
not better than ± 1μm

LINEARITY

The closeness to which the actual calibration curve approximates a straight line.” (IEC 1336, 1.3.26)

Linearity ≤ ± 0.05% from the set thickness, not better than ± 1μm

Accura Thickness Gauge Gallery

You May Also Be Interested In

Perfecta Thickness Gauge

The Industry Standard In Coating Weight Gauging

GGC Width Gauge

The Industry Standard In Coating Weight Gauging

Contact Us Today

With our partners in Europe and Asia, we have a worldwide reach. We provide the complete system engineering, design, fabrication, and installation – along with knowledgeable service and availability when you need us, regardless of your spot on the globe. Let us show you how we can help with your gauge needs.

Ready to Take the Next Step?