Global Gauge Corporation
ACCURA SERIES · 200 KV · EMERSON RIO

Accura-200
Thickness Gauge

200 kV constant-potential X-ray thickness gauge for hot and cold mill strip on Emerson DeltaV. Sub-2 ms response, ± 0.1% accuracy, factory-validated for RIO-standardized mills.

THICKNESS RANGE
0.040 – 2.000 in.
ACCURACY
± 0.1%
RESPONSE TIME
< 2 ms
X-RAY SOURCE
200 kV
Doc A200-26 · Rev CReplaces A200-23ISO/IEC 17025 calibrated
[PRODUCT PHOTO · ACCURA-200 C-FRAME]
Front
Side
Head
Cabinet
HOW IT WORKS

X-ray transmission, end to end

01

Non-contact X-ray source

Constant-potential 200 kV X-ray transmission through the strip, stable across mill temperature swings.

02

Solid-state detection

Ionization chamber detector with temperature compensation, calibrated per ISO/IEC 17025.

03

Real-time signal processing

Proprietary algorithms correct for alloy, pass line, and strip temperature in under 2 ms.

04

Emerson DeltaV integration

Published thickness to Emerson DeltaV over RIO for AGC loop closure.

FULL SPECIFICATIONS

Accura-200 technical data

Measurement
Measurement principleX-ray transmission, constant potential
Thickness range0.040 to 2.000 in. (1.02 to 50.8 mm)
Accuracy± 0.1% of nominal
Response time< 2 ms to 63% step
Repeatability (2σ)± 0.05% of nominal
Alloy compensation18 alloys standard, unlimited custom
X-ray Source
Source typeConstant-potential, air-cooled
Tube voltage200 kV maximum
Tube current1 to 10 mA, software-set
Warm-up time< 3 minutes from cold start
Controls & Electrical
Control platformEmerson DeltaV (RIO native)
ProtocolFoundation Fieldbus, OPC UA
HMIEXOR MicroEdge 15.6 in. color touch
Power208/240/480 VAC, 50/60 Hz, 3 kVA
Mechanical
Frame typeC-frame, motorized retract
Throat depth24 in. (610 mm) standard
Strip speedUp to 3,000 ft/min (914 m/min)
Ambient temperature0 to 50 °C operating
SPEC THE ACCURA-200

Get a budgetary quote.

Tell us your strip dimensions, line speed, and existing PLC architecture. Our applications team will return a complete proposal with installation schedule.